Ability
Railway Rolling-Fire testing
 
  • NF F 16-101 – Railway Rolling Stock Fire Behavior Choice of Materia
  • NF F 16-102 – Railway Rolling Stock Fire Behavior Choice of Material – Application for electrical equipment
    • > M Ranking (M0-M4):
      • - NF P 92-510: Determination of upper calorific potential
      • - NF P 92-501: Safety against fire: Building materials – Reaction to fire tests. used for rigid material or flexible materials thicker than 5mm
      • - NF P 92-503: Safety against fire - Building materials -Reaction to fire tests - Electrical burner test used for flexible materials
      • - NF P 92-504: Safety against fire - Building materials - Reaction to fire tests - Flame persistence test and speed of the spread of flame.
      • - NF P 92-505: Safety against fire - Building materials - Reaction to fire tests - Test used for thermal melting materials - Dripping test.
      • - NF P 92-507: Fire safety - Building - Interior fitting materials - Classification according to their reaction to fire
    • > I Ranking (I0-I4):
      • - NF ISO 4589-2:Plastics - Determination of burning behaviour by oxygen index - Part 2: Ambient - temperature test
      • - NF EN 60695-2-1:Fire Hazard Testing
    • > F Ranking (F0-F5):
      • - NF X10-702:Fire test methods – Smoke emission – Test of measurement of specific optical density of smoke by the combustion or the pyrolysis of solid materials
      • - NF X70-100:Fire behaviour tests – Analysis of pyrolysis and combustion gases – Pipe still method
    • > Cabel & Wire:
      • - NF C32-070:Fire behaviour tests – Analysis of pyrolysis and combustion gases – Pipe still method
  • PrCEN/TS 45545-2: Fire protection of railway vehicles - Part 2: Requirement for fire behaviours of materials and components (EN 45545-2)
    • - EN ISO 1182 Reaction to fire tests for building products. Non-combustibility test
    • - EN ISO 1716: Reaction to fire tests for building products. Determination of the heat of combustion
    • - EN ISO 9239-1 Reaction to fire tests for floorings. Part 1: Determination of the burning behaviour using a radiant heat source
    • - EN ISO 11925-2: Reaction to fire tests. Ignitability of building products subjected to direct impingement of flame . Part 2: Single-flame source test Plastics -- Determination of burning behaviour by oxygen index -- Part 2: Ambient-temperature test
    • - NF X10-702:Fire test methods – Smoke emission – Test of measurement of specific optical density of smoke by the combustion or the pyrolysis of solid materials
    • - NF X70-100:Fire behaviour tests – Analysis of pyrolysis and combustion gases – Pipe still method
    • - EN ISO 5659-2:Plastics -- Smoke generation -- Part 2: Determination of optical density by a single-chamber test
    • - EN ISO 5658-2, Reaction to fire tests. Spread of flame. Lateral spread on building products in vertical configuration
    • - EN ISO 5660-1: Reaction-to-fire tests -- Heat release, smoke production and mass loss rate -- Part 1: Heat release rate (cone calorimeter method)
    • - EN ISO 12952-3: Texitile. Flammability
    • - DIN EN 50266-2-4: Common Test Methods for Cables under Fire Conditions - Test for Vertical Flame Spread of Vertically-Mounted Bunched Wires or Cables Part 2-4: procedures – Category C
    • - DIN EN 50305: Railway applications. Railway rolling stock cables having special fire performance. Test methods
    • - DIN EN 50306-1:Railway applications - Railway rolling stock cables having special fire performances - Thin wall - Part 1: General requirements
    • - DIN EN 60332-1-2:Tests on electric and optical fibre cables under fire conditions Part 1-2: Test for vertical flame propagation for a single insulated wire or cable Procedure for 1 kW pre-mixed flame
    • - DIN EN 60332-2-2:Tests on electric and optical fibre cables under fire conditions Part 2-2: Test for vertical flame propagation for a single small insulated wire or cable Procedure for diffusion flame
    • - DIN EN 61034-1: Measurement of smoke density of cables burning under defined conditions Part 1: Test apparatus
Building Materials
 
  • M Ranking (M0-M4):
    • - NF P 92-510: Determination of upper calorific potential
    • - NF P 92-501: Safety against fire: Building materials – Reaction to fire tests. used for rigid material or flexible materials thicker than 5mm
    • - NF P 92-503: Safety against fire - Building materials -Reaction to fire tests - Electrical burner test used for flexible materials
    • - NF P 92-504: Safety against fire - Building materials - Reaction to fire tests - Flame persistence test and speed of the spread of flame.
    • - NF P 92-505: Safety against fire - Building materials - Reaction to fire tests - Test used for thermal melting materials - Dripping test.
    • - NF P 92-507: Fire safety - Building - Interior fitting materials - Classification according to their reaction to fire
  • EuroClasses EN 13501-1 (A1, A2, B, C, D, E, F):
    • - EN 13823: Reaction to fire tests for building products. Building products excluding floorings exposed to the thermal attack by a single burning item
    • - EN ISO 1182 Reaction to fire tests for building products. Non-combustibility test
    • - EN ISO 1716: Reaction to fire tests for building products. Determination of the heat of combustion
    • - EN ISO 9239-1 Reaction to fire tests for floorings. Part 1: Determination of the burning behaviour using a radiant heat source
    • - EN ISO 11925-2: Reaction to fire tests. Ignitability of building products subjected to direct impingement of flame . Part 2: Single-flame source test
Aircraft Materials
 
  • ABD 0031 Airbus Fire Test
    • Vertical Flammability Test: ABD 0031- 7.1.2 (AITM 2.0002 B/A)
    • Smoke Density Test: ABD 0031- 7.3.1 (AITM 2.0007)
    • Smoke Toxicity Test: ABD 0031- 7.4 (AITM 3.0005)
    • Heat Release Test: ABD 0031 (AITM 2.0006)
    • Horizontal Test: ABD 0031- 7.1.3 / -7.1.4 (AITM 2.0003)
    • 45° flammability test: ABD 0031- 7.1.5
  • Far 25.853 Fire test to aircraft material
    • Vertical flammability test: 14 FAR 25.853 b(4)), (App. F to part 25 part I § (a)
    • Smoke Density Test: 14 FAR 25.853 (d), (App. F to part 25, part V)
    • Heat Release Test: 14 FAR 25.853 (d), Appendix F, Part IV
    • Seat Test: 14 FAR 25.853 (c, App.F to part II)
    • Horizontal Test: 14 FAR 25.853 b(2,3), (App. F to part 25 part I § (a),(1)
    • 45° flammability test: 14 FAR 25.853 (b), (App. F to part 25, part I § (6))
Upholstered furniture and textile
 
  • - BS 5852-2006: Ignitability of upholstered seating by smouldering and flaming ignition sources
  • - BS EN 1021 Furniture-Assessment of the ignitability of upholstered furniture
  • - EN 597: Furniture-Assessment of the ignitability of mattresses and upholstered bed bases
Motor Vehicles Interior
 
  • - TL1010 burning behaviour-Volkswagen Standard
  • - 95/28/EC The burning behaviour of materials used in the interior construction of certain categories of motor vehicle
  • - NF P 92-505 Safety against fire - Building materials - Reaction to fire tests - Test used for thermal melting materials - Dripping test
  • - U.T.A.C 18-502 T1 burning behaviour of materials used in the interior construction of certain categories of motor vehicles
  • - FMVSS 302 Flammability of materials used in the occupant compartments of motor vehicles
Electrical & Electronic Device
 
  • - UL 94: Test for Flammability of Plastic Materials for Parts in Devices and Applia
  • - NF ISO 4589-2:Plastics – Determination of burning behaviour by oxygen index – Part 2: Ambient- temperature test
  • - NF EN 60695-2-1:Fire Hazard Testing
  • - NF C32-070:Insulated conductors and cables for installation – Classification tests on conductors and cables with regards to fire behaviour
  • - DIN EN 50266-2-4: Common Test Methods for Cables under Fire Conditions - Test for Vertical Flame Spread of Vertically-Mounted Bunched Wires or Cables Part 2-4: procedures – Category C
  • - DIN EN 50266-2-5: Common Test Methods for Cables under Fire Conditions - Test for Vertical Flame Spread of Vertically-Mounted Bunched Wires or Cables Part 2-5: procedures – Category D
  • - DIN EN 50305: Railway applications. Railway rolling stock cables having special fire performance. Test methods
  • - DIN EN 50306-1:Railway applications - Railway rolling stock cables having special fire performances - Thin wall - Part 1: General requirements
  • - DIN EN 60332-1-2:Tests on electric and optical fibre cables under fire conditions Part 1-2: Test for vertical flame propagation for a single insulated wire or cable Procedure for 1 kW pre-mixed flame
  • - DIN EN 60332-2-2:Tests on electric and optical fibre cables under fire conditions Part 2-2: Test for vertical flame propagation for a single small insulated wire or cable Procedure for diffusion flame
  • - DIN EN 61034-1: Measurement of smoke density of cables burning under defined conditions Part 1: Test apparatus
Fire Resistance Tests
 
  • - EN 1634-1: Fire resistance and smoke control tests for door. shutter and openable window assemblies and elements of building hardware - Part 1: Fire resistance tests for doors. shutters and openable windows
  • - EN 1363-1: Fire Resistance Tests - Part 1: General Requirements
  • - EN 1363-2: Fire Resistance Tests - Part 2: Alternative and Additional Procedures
  • - EN 1364-2: Fire Resistance Tests for Non-Loadbearing Elements - Part 2: Ceilings
  • - EN 1364-3: Fire resistance tests for non-loadbearing elements - Part 3: Curtain walling - Full configuration
  • - EN 1364-4: Fire resistance tests for non-loadbearing elements - Part 4: Curtain walling - Part configuration
  • - EN 1366-1: Fire Resistance Tests for Service Installations - Part 1: Ducts
  • - EN 1366-2: Fire Resistance Tests for Service Installations - Part 2: Fire Dampers